Neumann - KM 184 A Agrandir l'image
KK 184
Acoustic operating principle Pressure gradient transducer
Directional pattern Cardioid
Frequency range 20 Hz...20 kHz
Sensitivity1) 15 mV/Pa
Rated impedance 50 ohms
Rated load impedance 1000 ohms
Equivalent noise level, CCIR3) 22 dB
Equivalent noise level, A-weighted3) 13 dB-A
Signal-to-noise ratio2) CCIR3) 70 dB
Signal-to-noise ratio2) A-weighted3) 81 dB
Max SPL (THD<0.5%) 138 dB
Max SPL (THD<0.5%) with preattenuation 148 dB
Supply voltage (P48, IEC 61938) 48 V
Current consumption (P48, IEC 61938) max. 3.5 mA
Matching connector XLR 3 M
Weight output stage 70 g
Weight capsule 15 g
Diameter 22 mm
Length 188 mm

Plus de détails

NEUM46AF84

Nouveau

0 € HT

Prix conseillé: 0 €
Vous économisez: 0 € (0.00 %)

Neumann - KM 184 A

Neumann

The Neumann KM A Miniature Microphone System

The modular KM A miniature microphone system is a further development of the successful KM 100 series. The newly developed passive capsule design is available with 8 different directional characteristics, and can be combined modularly as desired with an analog (KM A) output stage in accordance with the AES 42 standard. The new, considerably smaller microphone capsules and an extensive program of accessories permit excellent adaptation of the microphone system to a wide range of applications.

Through the use of the most up-to-date electronic components the system offers many electroacoustic and operational advantages, such as lower self-noise, a wider dynamic range and very high immunity to electromagnetic interference. The acoustics of the capsules were taken from the proven KM 100 system.

Overview of Microphone Capsules

  • KK 184: Cardioid

KM A Output Stage

The KM A analog output stage with P48 phantom power has a switch for pre-attenuation of 10 dB. The microphones can thus handle levels of up to 152 dB (depending on the capsule type).

The dimensions (diameter 22 mm, length 93 mm) of the analog and digital output stages are identical. As a result, all accessories can be used in combination with both output stages. Upon request, a mechanical adapter can be supplied to adapt microphone capsules of the KM 100 system (AK series) to the KM A output stages.

The modular solution permits the microphone capsule to be separated from the output stage by a distance of up to 100 m. The LC 4 microphone cable with a length of 5 or 10 meters is available as a standard solution. Alternatively, capsule extensions of different lengths, swivel joints and stand mounts, etc., can be used for a flexible system setup.

The capsule heads KK 183, KK 184 or KK 185, together with the appropriate output stage, are also available as a set, in which case they are referred to as KM 183 A, etc.

Features And Specs

KK 184
Acoustic operating principle Pressure gradient transducer
Directional pattern Cardioid
Frequency range 20 Hz...20 kHz
Sensitivity1) 15 mV/Pa
Rated impedance 50 ohms
Rated load impedance 1000 ohms
Equivalent noise level, CCIR3) 22 dB
Equivalent noise level, A-weighted3) 13 dB-A
Signal-to-noise ratio2) CCIR3) 70 dB
Signal-to-noise ratio2) A-weighted3) 81 dB
Max SPL (THD<0.5%) 138 dB
Max SPL (THD<0.5%) with preattenuation 148 dB
Supply voltage (P48, IEC 61938) 48 V
Current consumption (P48, IEC 61938) max. 3.5 mA
Matching connector XLR 3 M
Weight output stage 70 g
Weight capsule 15 g
Diameter 22 mm
Length 188 mm

Commander

Neumann - KM 184 A

Neumann - KM 184 A

0 €

Veuillez patientez...

Pour le moment, M2M Pro a choisi la relation directe avec ses clients.
Les ventes, demandes d'offres et prix... se font via ce formulaire.
N'hésitez pas à prendre contact avec nous pour toute autre question.












* Champ requis