Microphones  Il y a 160 produits.

  • Afficher :
par page
  • Element: Ribbon Polar Pattern: Figure-of-eight Frequency Response: 20-18,000 Hz Open Circuit Sensitivity: –39 dB (11.2 mV) re 1V at 1 Pa Impedancet: 100 ohms Maximum Input Sound Level: 150 dB SPL, 1 kHz at 1% T.H.D. Noise: 22 dB SPL Dynamic Range (Typcial): 128 dB, 1 kHz at Max SPL Signal-to-Noise Ratio: 72 dB, 1 kHz at 1 Pa Phantom Power Requirements:...

  • Element: Fixed-charge back plate, permanently polarized condenser Polar pattern: Cardioid Frequency response: 20 – 20,000 Hz Impedance: 50 ohms Open circuit sensitivity: –25 dB (56.2 mV) re 1V at 1 Pa* Maximum input sound level: 142 dB SPL, 1 kHz at 1% T.H.D. Noise: 5 dB SPL Dynamic range (typical): 137 dB, 1 kHz at Max SPL Signal-to-noise ratio: 89 dB, 1...

  • Element Fixed-charge back plate, permanently polarized condenser Polar Pattern Cardioid Frequency Response 20 - 20,000 Hz Open Circuit Sensitivity -35 dB (17.7 mV) re 1V at 1 Pa* Impedance 100 ohms Maximum Input Sound Level 149 dB SPL, 1 kHz at...

  • Transducer Type: Condenser, Pressure GradientPolar Patterns: Cardioid Frequency Response: 20Hz – 20kHz Sensitivity: 39.8 mV/Pa at 1 kHz (1 pa = 94 dB SPL)Output Impedance: 50 ohmRate Load Impedance: Not less than 1k ohmMaximum SPL: 134dB SPL (1kHz, THD 0.5%)S/N Ratio: 83.2 dB-ANoise Level: 10.8 dBDynamic Range: 123.2 dBPower Requirement: +48V DC Phantom...

  • Transducer Type: Condenser, Pressure GradientPolar Patterns: Cardioid Frequency Response: 20Hz – 20kHz Sensitivity: 28.5 mV/Pa at 1 kHz (1 pa = 94 dB SPL)Output Impedance: 50 ohmRate Load Impedance: Not less than 1k omhMaximum SPL: 138dB SPL (0.5%)S/N Ratio: 82.3 dB-ANoise Level: 11.7Dynamic Range: 126.3 dBPower Requirement: +48V DC Phantom PowerWeight:...

  • Transducer Type : Condenser, Pressure GradientPolar Pattern : CardioidFrequency Response : 20Hz – 20KHzSensitivity : 20.0mV/Pa at 1kHz (1Pa = 94dB SPL)Output Impedance : 150ΩRated Load Impedance : >1 kΩMaximum SPL : 140 dB SPL (2.5kΩ, 0.5% THD)S/N Ratio : 86 dB–A (IEC 651)Noise Level : 9.0 dB–A (IEC651)Dynamic Range : 131 dB (@2.5kΩ)Power Requirement :...

  • Transducer Type: Vacuum Tube Condenser Polar Patterns: Various (Capsule-dependent)Frequency Response: 20Hz – 20kHzSensitivity: 20.0 mV/Pa at 1kHz (1Pa = 94dB SPL) w/B6 Capsule Output Impedance: 200ΩRated Load Impedance: Not less than 1kΩMaximum SPL: 134 dB SPL (2.5kΩ, 0.5% THD) w/B6 CapsuleS/N Ratio: 56.5 dB-A (IEC 651) w/B6 CapsuleNoise Level: 7.5 dB-A...

  • Transducer Type: Vacuum Tube Condenser Polar Patterns: Various (Capsule-dependent) Frequency Response: 20Hz – 20kHz Sensitivity: 20.0 mV/Pa at 1kHz (1Pa = 94dB SPL) w/B6 Capsule Output Impedance: 200Ω Rated Load Impedance: Not less than...

  • Acoustical operating principal Pressure gradient or pure pressure (depending on capsule)Directional pattern Cardioid, omnidirectional, figure of 8 (depending on capsule)Frequency response 20Hz – 20kHzSensitivity (1kHz into 2.5kΩ) 27mV/Pa (+/−10mV depending on capsule)Rated impedance 50ΩRated load impedance Not less than 1kΩNoise level a-weighted (iec 651)...

  • Transducer Type Vacuum Tube Condenser Polar Pattern Multipattern Frequency Response 20Hz – 20kHz Sensitivity 18.0mV/Pa at 1kHz (1 Pa=94dB SPL) Output Impedance 50ohms Rated Load Impedance >1k ohm Maximum SPL 134 dB SPL (2.5k ohms, 0.5% THD) S/N Ratio 84 dB-A (IEC 651) Noise Level 10 dB-A (IEC 651) Dynamic Range 124 dB (@ 2.5k ohms) Power Requirement...

  • Acoustical Operating Principal Pressure GradientDirectional Pattern CardioidFrequency Range 20Hz – 20KHzSensitivity at 1 kHz into 1k ohms 21mV/PaOutput Impedance 50 ohmsRated Load Impedance Not less than 1k ohmsS/N ratio CCIR468-3 75dBS/N ratio DIN/IEC 651 86dB-ANoise Level DIN/IEC 651 8dB-AMax SPL (0.5% THD) into 2.5k ohms 140dBDynamic Range...

Résultats 37 - 48 sur 160.