Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid/cardioid/supercardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 4.5 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 28 dB Equivalent noise level, A-weighted1) 18 dB-A Signal-to-noise ratio, CCIR1)...
Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid/cardioid/supercardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 4.5 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 28 dB Equivalent noise level, A-weighted1) 18 dB-A Signal-to-noise ratio, CCIR1)...
Acoustical operating principle Pressure transducer Directional pattern Ear Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 20 mV/Pa Rated impedance 50 ohms balanced, 200 ohms unbalanced Rated load impedance 1 kohms Equivalent noise level, CCIR1) 29 dB Equivalent noise level, A-weighted1) 16 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB...
Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 20 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 24 dB Equivalent noise level, A-weighted1) 12 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 70 dB...
Acoustical operating principle Pressure gradient transducer Directional pattern Omnidirectional, wide angle cardioid, cardioid, hypercardioid, figure-8 plus one intermediate position each Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 34/47/62 mV/Pa1) Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR2)...
Acoustical operating principle Pressure transducer Directional pattern Omnidirectional Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 20 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 28 dB Equivalent noise level, A-weighted1) 15 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 66 dB...
Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 11 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 21 dB Equivalent noise level, A-weighted1) 12 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 73 dB...
Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 23 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 17.5 dB Equivalent noise level, A-weighted1) 7 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 76.5 dB...
Acoustical operating principle Pressure gradient transducer Directional pattern Omni, wide angle cardioid, cardioid, hypercardioid, figure-8 Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohms 11 mV/Pa Rated impedance 50 ohms Rated load impedance 1000 ohms Equivalent noise level, CCIR1) 22 dB Equivalent noise level, A-weighted1) 10 dB-A...
Acoustical operating principle Pressure gradient transducer Directional pattern Omnidirectional, wide angle cardioid, cardioid, hypercardioid, figure-8 Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 8 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 26 dB Equivalent noise level, A-weighted1) 14...
Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohms 18 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 21 dB Equivalent noise level, A-weighted1) 10 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 73 dB...
Acoustical operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 13 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 23 dB Equivalent noise level, A-weighted1) 12 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 71 dB...