  • Acoustical operating principle Pressure/Pressure gradient transducer Directional pattern omnidirectional/cardioid/hypercardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 12mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 24 dB Equivalent noise level, A-weighted1) 13 dB-A Signal-to-noise...

  • KK 183 Acoustic operating principle Pressure transducer Directional pattern omni diffuse-field equalized Frequency range 20 Hz...20 kHz Sensitivity1) 12 mV/Pa Rated impedance 50 ohms Rated load impedance 1000 ohms Equivalent noise level, CCIR3) 24 dB Equivalent noise level, A-weighted3) 13 dB-A Signal-to-noise ratio2) CCIR3) 69 dB Signal-to-noise ratio2)...

    0 €HTVA
  • Acoustical operating principle Pressure/Pressure gradient transducer Directional pattern omnidirectional/cardioid/hypercardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 12/15/10 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 22 dB Equivalent noise level, A-weighted1) 13 dB-A...

  • KK 184 Acoustic operating principle Pressure gradient transducer Directional pattern Cardioid Frequency range 20 Hz...20 kHz Sensitivity1) 15 mV/Pa Rated impedance 50 ohms Rated load impedance 1000 ohms Equivalent noise level, CCIR3) 22 dB Equivalent noise level, A-weighted3) 13 dB-A Signal-to-noise ratio2) CCIR3) 70 dB Signal-to-noise ratio2)...

    0 €HTVA
  • Acoustical operating principle Pressure/Pressure gradient transducer Directional pattern omnidirectional/cardioid/hypercardioid Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 10 mV/Pa Rated impedance 50 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 24 dB Equivalent noise level, A-weighted1) 15 dB-A Signal-to-noise...

  • KK 185 Acoustic operating principle Pressure gradient transducer Directional pattern Hypercardioid Frequency range 20 Hz...20 kHz Sensitivity1) 10 mV/Pa Rated impedance 50 ohms Rated load impedance 1000 ohms Equivalent noise level, CCIR3) 24 dB Equivalent noise level, A-weighted3) 15 dB-A Signal-to-noise ratio2) CCIR3) 69 dB Signal-to-noise ratio2)...

    0 €HTVA
  • Technical data KM A + KK 131 KK 133 KK 183 Acoustic operating principle Pressure transducer Pressure transducer Pressure transducer Directional pattern omni free-field equalized omni diffuse-field equalized omni diffuse-field equalized Frequency range 20 Hz...20 kHz 20 Hz...20 kHz 20 Hz...20 kHz Sensitivity1) 12 mV/Pa 15 mV/Pa 12 mV/Pa Rated impedance...

  • Technical data KM D + KM D + KK 131 KK 133 KK 183 Acoustic operating principle Pressure transducer Pressure transducer Pressure transducer Directional pattern omni free-field equalized omni diffuse-field equalized omni diffuse-field equalized Frequency range 20 Hz...20 kHz 20 Hz...20 kHz 20 Hz...20 kHz Sensitivity1) -41 dBFS -40 dBFS -41 dBFS Equivalent...

  • Acoustical operating principle Interference transducer Directional pattern Supercardioid/lobe Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 18 mV/Pa Rated impedance 150 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 23 dB Equivalent noise level, A-weighted1) 12 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 71...

  • Acoustical operating principle Interference transducer Directional pattern Supercardioid/lobe Frequency range 20 Hz ... 20 kHz Sensitivity at 1 kHz into 1 kohm 21 mV/Pa Rated impedance 150 ohms Rated load impedance 1 kohms Equivalent noise level, CCIR1) 23 dB Equivalent noise level, A-weighted1) 12 dB-A Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 71...

Résultats 25 - 36 sur 54.