Large diaphragm cardioid tube microphone Genuine platinum coated 4µm capsule Innovative class-A zero feedback amp Remote adjustable dynamic range Integrated pop filter
All-Tube triode design 12AT7 (2011 build. Previous versions used 12AX7 and 6072.) -10 dB switchable pad Frequency response: 10Hz-30KHz Sensitivity: 17mV/Pa Noise typically -120dB EIN Max SPL: 150dB Actual output impedance 200 Ohms Weight: 2.25 lbs (mic) Weight: 2.5 lbs (PSU) Size: 4.5" x 9.7" x 4.5" (mic) Size: 5" x 8.2" x 3.4" (PSU) Shipping weight: 15...
All-Tube triode design 12AT7 (2011 build. Previous versions used 12AX7 and 6072.) -10 dB switchable pad Frequency response: 10Hz-30KHz Sensitivity: 17mV/Pa Noise typically -120dB EIN Max SPL: 150dB Actual output impedance 200 Ohms Weight: 2.25 lbs (mic) Weight: 2.5 lbs (PSU) Size: 4.5" x 9.7" x 4.5" (mic) Size: 5" x 8.2" x 3.4" (PSU) Shipping weight: 15...
Condenser Microphone Transducer USA Hand Made Capsule by Josephson Audio Capsule is based on the Vintage Sony C-37A Single-Sided Large Diaphragm Capsule 5 Micron Evaporated Gold Diaphragm Dual Pattern Cardioid or Omni Directional Adjustable Vent on the Backplate Changes the Pattern 5670 Internal Vacuum Tube Head Amplifier Constant Current...
Polar pattern CardioidAcoustic operating principle Pressure gradient transducerFrequency range 40...20000 HzSensitivity at 1 kHz 21 mV/PaOutput impedance 100 OhmsNoise levelCCIR 468 - 4 13 dBDIN EN 60651 7 dB - ASignal-to-noise ratio (re 1 Pa at 1 kHz)CCIR - weighted 81 dBA - weighted 87 dBMax. SPL for K < 0,5% 142 dBMax. output levelRL = 1 k Ohms 17...
Polar pattern OmniAcoustic operating principle Pressure transducerFrequency range 20 … 20000 Hz ± 2 dBSensitivity at 1 kHz 50 mV / PaOutput impedance 100 ΩNoise level CCIR 468-4: 28 dBDIN EN 60651: 15 dB ( A )Signal-to-noise ratioA-weighted: 79 dBMax. output levelRi = 1 kΩ: 18 dBuRi = 100 kΩ: 19 dBuMax. SPL for K < 0,5 % 136 dBDynamic range 121...
Polar pattern cardioidAcoustical operating principle Pressure gradient transducerFrequency range 40 ... 18000 HzSensitivity at 1 kHz 17 mV / PaSwitch position "reduced bass roll-off" at 60 Hz -15 dBRated impedance 150 OhmsEquivalent loudness level due to inherent noise CCIR 468-4 22 dB DIN EN 60651 13 dB - ASignal-to-noise-ratio (re. 1 Pa at 1 kHz)...
Polar pattern OmniAcoustical operating principle Pressure transducerFrequency range 20 ... 20000 Hz ± 2,5 dBSensitivity at 1 kHz 15 mV / PaSwitch position "reduced bass roll-off" at 90 Hz -10 dBRated impedance 150 OhmsEquivalent loudness level due to inherent noise CCIR 468-4 22 dB DIN EN 60651 14 dB - ASignal-to-noise-ratio (re. 1 Pa at 1 kHz)...
Polar pattern CardioidAcoustical operating principle Pressure gradient transducerFrequency range 40 ... 18000 HzSensitivity at 1 kHz 12 mV / PaOutput impedance 100 OhmsEquivalent loudness level due to inherent noise CCIR 468-4 26 dB DIN EN 60651 16 dB - ASignal-to-noise-ratio (re. 1 Pa at 1 kHz) CCIR-weighted 68 dB A-weighted 78 dBMax. SPL for THD <...
Polar-pattern Super-cardioidAcoustic operating principle Pressure-gradient transducerFrequency range 20 - 20,000 HzSensitivity @ 1kHz 17mV/PaOutput impedance 100 OhmsEquivalent loudness level due to inherent noise CCIR 468-4 23dB DIN EN 60651 13dB-ASignal to Noise ratio (1Pa at 1kHz) CCIR-weighted 71dB A-weighted 81dBMax SPL for THD "0.5% 147dBTotal...